Table: Platform Alarms
Alarm Message |
Repair Action |
CMOS Battery Error |
|
CMOS Checksum Error |
- Replace the motherboard.
- If Step 1 does not work, run the CMOS setup.
|
Display Card Mismatch |
|
Diskette Drive Controller Error or Not Installed |
Check the diskette cable connections. |
Diskette Drive Error |
Diskette may be defective. If the diskette is good, replace the diskette drive. |
Diskette Drive A Type Mismatch |
Run the CMOS setup and select the proper drive type. |
Diskette Drive B Type Mismatch |
Run the CMOS setup and select the proper drive type. |
Equipment Configuration Error. |
Check the memory configuration:
- Check the MAP/5PV3 DIMM or the MAP/5P SIMM seating.
- Check the CMOS setup.
|
Hard disk Controller Error |
|
Hard disk 0 Error |
Check all cable connections. |
Keyboard Error or No Keyboard Connected |
Check and connect the keyboard to the MAP/5P. |
Keyboard Interface Error |
Replace the keyboard. |
Memory Error at: MMMM:SSSS:OOO (W:XXXX, R:YYYY) where: M is Mbytes, S is Segment, O is Offset, X/Y are write/read pattern |
For the MAP/5P, replace the SIMMs. For the MAP/5PV3, replace the DIMM. |
CPU Clock Mismatch |
- Run the CMOS setup and check the CPU clock setting.
- If the clock setting is correct, reboot the system.
- If the error persists, contact the remote maintenance service center.
|
Onboard Serial Port 1 Conflict |
Run the CMOS setup and disable the port. |
Onboard Serial Port 2 Conflict |
Run the CMOS setup and disable the port. |
Onboard Parallel Port Conflict |
Run the CMOS setup and disable the port. |
Pointing Device Error |
Run the CMOS setup and disable the PS/2 mouse. A mouse is not used with this system. |
Pointing Device Interface error |
Run the CMOS setup and disable the PS/2 mouse. A mouse is not used with this system. |
Press F1 key to continue or B+A+^ for setup. |
Press F1 to continue. |
Real Time Clock Error |
|