more topics

Remote Access Feature

System Programming

Remote Access Trunk Assignment  

Programmable by

System Manager

Mode

All

Idle Condition

Not required

Planning Form

3a, Incoming Trunks: Remote Access

Factory Setting

Remote Access is not assigned

Valid Entries Dedicated, Shared, No Remote
Inspect Yes
Copy Option

No

Procedure

Assign dedicated or shared Remote Access to lines/trunks:

LinesTrunksRemoteAccssLinesTrunks
Dial line/trunk no.Enterspecify how trunk is used (Dedicated, Shared, No Remote)EnterBackBack

Remote Access without Barrier Codes  

Programmable by

System Manager

Mode

All

Idle Condition

Not required

Planning Form

3a, Incoming Trunks: Remote Access

Factory Setting

Call restriction: Outward restricted
ARS restriction level: 3

Valid Entries Unrestricted, Toll Restricted, Outward Restricted; 0 to 6
Inspect No
Copy Option

No

Procedure

If barrier codes are not used, assign class of restrictions to lines/trunks:

To change calling restrictions:

LinesTrunks RemoteAccssSelect Non-TIE or TIE LinesRestrictionSelect restrictionEnter
BackBackBackBack

To change ARS Facility Restriction Level:

LinesTrunks RemoteAccssSelect Non-TIE or TIE LinesARS RestrictDropDial FRL valueEnter
BackBackBackBack

To assign/remove Allowed Lists:

LinesTrunks RemoteAccssSelect Non-TIE or TIE LinesAllow ListDial list no.Enter
BackBackBackBack

To assign/remove Disallowed Lists:

LinesTrunks RemoteAccss Select Non-TIE or TIE LinesDisallowLstDial list no.Enter
BackBackBackBack

Remote Access with Barrier Codes  

Programmable by

System Manager

Mode

All

Idle Condition

Not required

Planning Form

3a, Incoming Trunks: Remote Access

Factory Setting

Calling restrictions:
Barrier Code: outward restricted
All other barrier codes: unrestricted
ARS restriction level: 3

Valid Entries Unrestricted, Toll Restricted, Outward Restricted;
0 to 6
Inspect No
Copy Option

No

Procedure

Assign class of restriction for each barrier code:

LinesTrunks RemoteAccssBarrierCode
Restriction
Dial barrier code no.EnterSelect restrictionEnter ARS RestrictDial barrier code no.EnterDropDial FRL valueEnterSelect Allow List or Disallow ListDial barrier code no. (1-16)Enter
Dial list no.Enter BackBackBackBack

Remote Access Barrier Codes  

Programmable by

System Manager

Mode

All

Idle Condition

Not required

Planning Form

3a, Incoming Trunks: Remote Access

Factory Setting

No barrier codes are established

Valid Entries Not applicable
Inspect No
Copy Option

No

Procedure

Specify that barrier codes are required for Remote Access:

To establish or remove code requirements:

LinesTrunks RemoteAccssSelect Non-TIE or TIE LinesBarrierCodeSpecify whether barrier codes are requiredEnter BackBackBack

To change barrier code length:

LinesTrunks RemoteAccssBarrierCodeCode InfoCode Length DropDial code lengthEnter
YesBackBackBack

To change barrier code:

LinesTrunks RemoteAccssBarrierCodeCode InfoCode Entry Dial code IDEnterDropDial codeEnter BackBackBack

 

Remote Access Automatic Callback  

Programmable by

System Manager

Mode

Hybrid/PBX

Idle Condition

Not required

Planning Form

3a, Incoming Trunks: Remote Access

Factory Setting

Disable

Valid Entries Disable, Enable
Inspect No
Copy Option

No

Procedure

Enable or disable Callback for busy pools:

LinesTrunks RemoteAccssAutoQueuingSelect
Enable or Disable EnterBackBack

Redirect Outside Calls to Unassigned Extension Numbers  

Programmable by

System Manager

Mode

All

Idle Condition

Not required

Planning Form

8a, System Features

Factory Setting

Extension number of primary operator

Valid Entries QCC queue extension number, other extension number
Inspect No
Copy Option

No

Procedure

Specify destination of Remote Access calls to unassigned numbers:

To select QCC queue:

Options or MoreUnassigned QCC Queue
EnterBack

To select extension or Calling Group:

Options or MoreUnassignedSelect Extension or Grp CallingEnterDial ext. no. or group no.
Enter Back

Topics
  Description
 
  Lines and Trunks
Table: Remote Access Routing
User Interaction
Class of Restriction
  At a Glance
  Considerations & Constraints
  System Programming
  Mode Differences
Feature Interactions