Avaya

Modular Messaging Help

 Getting Started 
 Administration 
 Maintenance 
 Reference 
 
Home > MSS Administration > System verification > LogsActivity log > System-Parameters Activity-Log screen; setting activity log options

System-Parameters Activity-Log screen; setting activity log options

Field Name Valid Input Description/Procedure
Activity Log Enabled?

Default:
n = yes

Valid input:
y = yes
n = no

Activates data collection for the activity log.
Record MWI Updates?

Default:
n = yes

Valid input:
y = yes
n = no

Activates the recording of message-waiting indicator (MWI) updates that are sent from the messaging system to the switch. MWI update records are written to the activity log file only if both the Activity Log feature and the recording of MWI updates are enabled.

Note: Enabling this feature increases the number of records written to the activity log.

Maximum Number of Activated Log Entries:

Default: 10000

Valid input:
From 1 to 99999

The maximum number of records in the activity log file.

Note: The system clears the log if this number is less than the number of records currently in the log. The system prompts you to confirm this action before continuing.

Clear All Entries in Activity Log?

Default:
n = yes

Valid input:
y = yes
n = no

Resets the entries in the activity log.

 

Top of page