set sync interface
Privilege: Configure
Description: set sync interface { primary | secondary } {<mmID>|<portID>}
Defines a potential stratum clock source (E1/T1 MM, ISDN-BRI) Setting source
to primary, normal failover will occur. Setting source to secondary overrides
normal failover, gen a trap, and assert a fault. Not stored in persistent
storage.
Parameters: <mmID> is the Media Module ID of a MM stratum clock source of
the form "vn" where "n" is the MM slot number. For BRI MM, a "portID" is
depicted by combining the mmID of the MM to the port number of the BRI port
furnishing the source.
Sample Display
MG-001-3(configure)# set sync interface primary v2
MG-001-3(configure)# set sync interface secondary v403