set sync source

	Privilege:		Configure
 

 
	Description:		set sync source {primary | secondary | local }
 
	Defines the stratum clock source (E1/T1 MM, ISDN-BRI) Setting source 
 
to primary, normal failover will occur. Setting source to secondary overrides 
normal failover, gen a trap, and assert a fault. Not stored in persistent 
storage.
 

 
Parameters: 			None.  'local' is default.
 

 
Sample Display

 
MG-001-3(configure)# set sync source primary
 

 
MG-001-3(configure)#
 

 
If the secondary interface is not configured, the sync source set operation 
will fail.
 
MG-001-3(configure)# set sync source secondary
 
	
 
Operation Failed
 

 
Cannot set the secondary clock source
 
to be the active clock source
 