Previous page Next page

Install External Ringing���

Connections for external ringing are at an information outlet. The media gateway side of the Main Distribution Frame (MDF) is connected to a TN2183 (or equivalent) Analog Line circuit pack. The circuitry and power source for the device are provided by the customer.

NOTE: A maximum of 3 devices can connect to 1 analog line circuit pack port.

  1. Wire the ringing device to the information outlet as shown in 3-Pair and 4-Pair Modularity and Example Adjunct Power Connections.
  2. Administer per the Administrator's Guide for Avaya MultiVantage Software.

3-Pair and 4-Pair Modularity


Figure notes

1 Port Circuit Pack
2 Media Gateway Connector Pins
(3-Pair Modularity)
3 Main Distribution Frame (MDF) Pins (3-Pair Modularity)
4 Input to Information Outlet
(4-Pair Modularity)
5 Adjunct Power
6 Output From Information Outlet
(4-Pair Modularity)
7 Voice or Data Terminal Pins


Previous page Next page