Previous page Next page

Connect an Analog Station or 2-Wire Digital Station���

This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500), analog Central Office (CO) trunks, Direct Inward Dial (DID) trunks, and external alarms. See 2500-Type Analog Telephone Wiring.

  1. Choose a peripheral to connect (such as a 2-wire digital station).
  2. Choose the port circuit pack to use and its carrier and slot number (from Port Circuit Pack and Telephone Pin Designations). For example: TN2183 Analog Line, Cabinet 1, Carrier C, Slot 1.
  3. Choose a port circuit on the port circuit pack, for example port 3.
  4. Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate pins on the port circuit pack.
  5. Administer using Administrator's Guide for Avaya MultiVantage Software.

2500-Type Analog Telephone Wiring���


Figure notes

1 2500-Type Analog Station
2 TN2183 Analog Line Circuit Pack, Position 1C01

Port Circuit Pack and Telephone Pin Designations�����
Pin on Modular Plug
4-wire: 8400-Series, 606A1
2-wire: 302D, 8400-Series, 603E
8510T BRI (with adjunct speaker phone)
Analog Station, Modem
NT1
1
TXT
�
�
�
�
2
TXR
�
�
T�
�
3
PXT
�
TXT
R
�
4
�
T
PXR
�
T
5
�
R
PXT
No Connection 4-pin modular jack
R
6
PXR
�
TXR
�
7
-48VDC
(-48VDC)
(-48VDC)
-48VDC
8
GRD
GRD
GRD
GRD
Circuit Pack
TN754C 4-wire digital
(8 port)
TN2181 2-wire digital (16 port)
TN2224 2-wire digital (24 port)
TN556D ISDN-BRI line
TN2183 Analog line (16 port)
TN2198 2-wire BRI line

PX�����PBX transmit���������T��Tip�����(A)
TX����Terminal transmit����R��Ring���(B)




Previous page Next page