Merlin Administration

 

This article provides general information on specifications for Merlin Plus Control Units.

 

Comcodes:

Item Comcode PEC Code
Merlin Plus R1 105414999 6122-CU1
Merlin Plus R2 105415012 6122-CU2
Control Unit Front Cover Panel R1 and R2 845695808 N/A
4 Line Card (no surge protection) 103982559 61225
4 Line Card (with surge protection) 105407092 61225
10 Station Expansion Module 103982542 61226
Memory Module R1 105202113 N/A
Memory Module R2 106308836 N/A

Control Unit:

  • Line jacks: 4 per line module, 8 max.
  • Station jacks: 10 per line module, 20 max.
  • Line Auxiliary jacks: 1 per line module, 2 max.
  • Paging jack: 4 pair, only 2 pairs used.
  • Music-on-Hold Interface: RCA phone type.

Dimensions:

  • 16 inches H x 11 inches W x 7 inches D

Weight (approx.):

  • 8 lb. (With one line and one station module).

Power:

  • Input to control unit from AC outlet.
  • 117 Volts AC ideal, range 99Vrms to 129 Vrms.
  • 60 Hertz (Hz) 0.1 Hz.
  • 1.4 Amps.
  • 165 Watts.
  • Merlin Control Unit looks for 23-35 milliamps on incoming line from Dial Tone Provider.
  • Three-prong outlet with proper third wire ground, separately fused at 15 amps, not controlled by a switch.
  • Battery Back Up should last 72 hours
  • Underwriter's laboratory (UL) listed.

BTU Rating - 561

Surge Protection:

  • External or internal depending on the configuration of the control unit.
  • Systems are completely protected internally only if they have an 820D1 or 820D2 cabinet, a protected power supply and protected line modules. All three must be present.
  • Cabinets are identified by the FCC label on the left outside panel and the metal grounding rail at the top.
  • Power Supplies are identified by the amber on-off switch and ground lug.
  • The Amber light should be lit when the switch is in the on position. If it is not lit, the outlet is dead, not wired properly or improperly grounded.
  • Line Module is identified by the W/P sticker above the third line jack and the metal tab at the top of the line board.
  • Systems require external protection with an 820D cabinet, when an unprotected power supply or an unprotected line module is present.
  • 145A/146A/147A surge protectors should be installed on systems that are not fully protected.
  • 145A/146A/147A surge protectors should not be installed on fully protected systems. If installed they should be removed and returned to the MSL.
  • All components, 820D, 820D1 and 820D2 cabinets, protected and unprotected power supplies, and protected and unprotected line modules are completely compatible.

FCC Registration Number:

  • AS593M-13529-KF-E.
  • REN 0.8A.
  • Fully Protected Key System under FCC Rules, Part 68.
  • Complies with FCC Rules, Part 15, Subpart J for Class A computing device suitable for commercial use (likely to cause interference in a residential area).

Local Exchange Carrier (Dial Tone Provider) Interface/Universal Service Ordering Code (USOC)

Local Exchange Carrier Interface Jacks

  • RJ11C (Single line jack).
  • RJ14C (Two line jack).
  • RJ21X (Multiline network interface).
  • Merlin Control Unit looks for 23-35 milliamps on incoming line from Dial Tone Provider.

Switching Method:

  • Analog, Space-Division.

Talk Paths:

  • Intercom paths = 3.
  • Simultaneous conversations = 11.

Line Type:

  • 2 Wire Loop Start or equivalent.

Line Port Impedance:

  • 600 Ohms.

Station Wiring:

  • 4 pair (See also Wiring Case).
  • Home Run/Star configuration-
  • Max Distance from Control Unit 1000 feet with 24-gauge wire or equivalent.
  • In range, out of building stations must be protected with IROB protectors.
  • Off-premise circuit can terminate on Merlin Plus with two-wire loop start line into line jack.
  • Merlin Plus can originate Off-premise station with the optional Merlin Off-Premise Module and an OL13C circuit from the Dial Tone Provider.

Environmental Factors:

  • Temperature Range 40F-104F.
  • Humidity Range 5%-80%.
  • Avoid dust, moisture, and any other airborne contaminants.
  • Avoid direct exposure to sunlight.
  • Minimum 1 inch space for ventilation above and to the sides.
  • Mounts vertically only.
  • Tolerates Radio Frequency field strengths of up to two volts per meter without effect on performance.

    See attachments.