Merlin Administration
This article provides general information on specifications for Merlin Plus Control Units.
Comcodes:
Item |
Comcode |
PEC Code |
Merlin Plus R1 |
105414999 |
6122-CU1 |
Merlin Plus R2 |
105415012 |
6122-CU2 |
Control Unit Front Cover Panel R1 and R2 |
845695808 |
N/A |
4 Line Card (no surge protection) |
103982559 |
61225 |
4 Line Card (with surge protection) |
105407092 |
61225 |
10 Station Expansion Module |
103982542 |
61226 |
Memory Module R1 |
105202113 |
N/A |
Memory Module R2 |
106308836 |
N/A |
Control Unit:
- Line jacks: 4 per line module, 8 max.
- Station jacks: 10 per line module, 20 max.
- Line Auxiliary jacks: 1 per line module, 2 max.
- Paging jack: 4 pair, only 2 pairs used.
- Music-on-Hold Interface: RCA phone type.
Dimensions:
- 16 inches H x 11 inches W x 7 inches D
Weight (approx.):
- 8 lb. (With one line and one station module).
Power:
- Input to control unit from AC outlet.
- 117 Volts AC ideal, range 99Vrms to 129 Vrms.
- 60 Hertz (Hz) 0.1 Hz.
- 1.4 Amps.
- 165 Watts.
- Merlin Control Unit looks for 23-35 milliamps on incoming line from Dial Tone Provider.
- Three-prong outlet with proper third wire ground, separately fused at 15 amps, not controlled by a switch.
- Battery Back Up should last 72 hours
- Underwriter's laboratory (UL) listed.
BTU Rating - 561
Surge Protection:
- External or internal depending on the configuration of the control unit.
- Systems are completely protected internally only if they have an 820D1 or 820D2 cabinet, a protected power supply and protected line modules. All three must be present.
- Cabinets are identified by the FCC label on the left outside panel and the metal grounding rail at the top.
- Power Supplies are identified by the amber on-off switch and ground lug.
- The Amber light should be lit when the switch is in the on position. If it is not lit, the outlet is dead, not wired properly or improperly grounded.
- Line Module is identified by the W/P sticker above the third line jack and the metal tab at the top of the line board.
- Systems require external protection with an 820D cabinet, when an unprotected power supply or an unprotected line module is present.
- 145A/146A/147A surge protectors should be installed on systems that are not fully protected.
- 145A/146A/147A surge protectors should not be installed on fully protected systems. If installed they should be removed and returned to the MSL.
- All components, 820D, 820D1 and 820D2 cabinets, protected and unprotected power supplies, and protected and unprotected line modules are completely compatible.
FCC Registration Number:
- AS593M-13529-KF-E.
- REN 0.8A.
- Fully Protected Key System under FCC Rules, Part 68.
- Complies with FCC Rules, Part 15, Subpart J for Class A computing device suitable for commercial use (likely to cause interference in a residential area).
Local Exchange Carrier (Dial Tone Provider) Interface/Universal Service Ordering Code (USOC)
Local Exchange Carrier Interface Jacks
- RJ11C (Single line jack).
- RJ14C (Two line jack).
- RJ21X (Multiline network interface).
- Merlin Control Unit looks for 23-35 milliamps on incoming line from Dial Tone Provider.
Switching Method:
Talk Paths:
- Intercom paths = 3.
- Simultaneous conversations = 11.
Line Type:
- 2 Wire Loop Start or equivalent.
Line Port Impedance:
Station Wiring:
- 4 pair (See also Wiring Case).
- Home Run/Star configuration-
- Max Distance from Control Unit 1000 feet with 24-gauge wire or equivalent.
- In range, out of building stations must be protected with IROB protectors.
- Off-premise circuit can terminate on Merlin Plus with two-wire loop start line into line jack.
- Merlin Plus can originate Off-premise station with the optional Merlin Off-Premise Module and an OL13C circuit from the Dial Tone Provider.
Environmental Factors: