A shutdown is required to replace hardware or
when a power outage is scheduled for the site.A shutdown may be done via the Reset System
Shutdown command or by pressing the Boot/Shutdown
button.
Boot/Shutdown button method:
- Use a pen or pin (not a pencil) to press the
Boot/Shutdown button on the front of the DEFAUD alarm board to
initiate a shutdown
- On the Liquid Crystal Display (LCD) on the
front of the DEFAUD Multi-Function Board (MFB), they will see'M_SHUT' flash on and off for about 3 minutes
- When 'M_SHUT' becomes steady, the shutdown
is complete
Remote or local terminal shutdown (DEFAUD up
and running):
- On the DEFAUD command line, type reset
system shutdown or rese s s. Press F3
- Press F3 and the shutdown will begin when
all the DEFAUD ports are idle. To force all ports to be idled,
press F3 when page 2 of the form is displayed
- When the shutdown is complete, the remote
connection will be dropped. If someone is onsite they can watch the
LCD on the front of the DEFAUD Multi-Function Board (MFB). You will
see 'M_SHUT' flash on and off for about 3 minutes. When 'M_SHUT'
becomes steady, the shutdown is complete
NOTES:
If the DEFAUD is being shutdown for a power
outage, the DEFAUD will begin to reboot as soon as power is
restored
If the DEFAUD was shutdown for hardware
replacement, the DEFAUD will begin to reboot as soon as the DEFAUD
is inserted back in the carrier
When a reboot is in progress, if the person
onsite watches the LCD, they will see the following (times are
approximate):
BTEST (40 seconds)
BOOT (10 seconds)
OSINIT (15 seconds)
AINIT (3 minutes)
ADX (This indicates that the reboot is
complete.)
If the DEFAUD does not begin to reboot
automatically, push the Boot/Shutdown button on TN2169/TN2170,
alarm board. (Or to start the reboot from a local or remote
terminal, if 'command menu:' is not displayed, simultaneously press
Ctrl+c twice. When 'command menu:' is displayed, enter 5 and press
Return to begin the reboot.)