To correct this issue, the configuration flash needs to be erased.
NOTE - This will factory default the unit and potentially the stack configuration if it is the base unit.
In order for the user to get the unit to boot up, the unit must be power cycled and Ctrl-C entered from the console port after the power on self test (POST) has started to run. The POST has started if "Testing main memory - " is displayed on the screen. Refer to the following screen display.
When the "Press" menu is displayed on the console, enter 'i' to initialize the config area of flash.
Enter 'y' to confirm. When the "Press" menu is redisplayed, enter 'a' to run the agent code. The unit should boot properly.
BayStack XXX Diagnostics X.X.X.X
Testing main memory - PASSED Enter Ctrl-C
>> Break Recognized - Wait.. Ctrl-C recognized
Resets: 58.
Initializing Flash..
Reading MAC Address..
MAC Address: 02:09:97:33:8A:60
Initializing Switch CBs,.......
Initializing Switch HW..
Press 'a' to run Agent code
Press 'd' to Download agent code
Press 'e' to display Errors
Press 'i' to Initialize config/log flash
Press 'p' to run POST tests.. ( Enter 'i')
Erase Config/Log Flash? y/N [ N ]: y (Enter 'y')
Erasing - Wait 2 sec..
Press 'a' to run Agent code
Press 'd' to Download agent
code
Press 'e' to display Errors
Press 'i' to Initialize config/log flash
Press 'p' to run POST tests.. (Enter 'a')
Starting Agent Code..
1
Decompressing the image ...
diskFormat(): "NVRAM:" found unformatted..."NVRAM:" formatted.
Target Name: vxTarget
User: target
Attaching network interface idtip0... done.
Attaching network interface lo0... done.
Completing initialization...
NOTE: Units exhibiting the symptoms described in this bulletin should NOT be returned through the RMA process. They should be corrected in the field.