Communication Manager: DIG-LINE test 16 aborts, error code 3, and test 17 aborts, error code 5


Doc ID    SOLN244102
Version:    1.0
Status:    Published
Published date:    30 Jan 2014
Author:   
Mark Christensen
 

Details

This article is relevant to any G3 or Communication Manager.

Problem Clarification

DIG-LINE test 16 aborts, error code 3, and test 17 aborts, error code 5.

Cause

More often than not, if DIG-LINE test 16 aborts, error code 3, and test 17 aborts, error code 5, the problem is with wiring.

Solution

Repair wiring at the jack.  If that doesn't fix it, move the digital phone (DCP phone) to the closest point to the cross-connect for the port that the station is assigned to. If the test fails there, too, make sure that the wiring is good to the digital port. You may also connect the phone to a known-good port. If the phone works there, the port is bad, and the circuit pack should be replaced. If the phone doesn't work there either, replace the phone.