DS1 high error rate and slippage


Doc ID    SOLN245199
Version:    2.0
Status:    Published
Published date:    29 Jan 2016
Created Date:    18 Feb 2014
Author:   
Roger Landry
 

Details

DS1 running high error rate and slips
board fails test 255 with error 8 on several ports during long test

09D1904     ISDN-TRK    0008/074         255       FAIL             8
09D1905     ISDN-TRK    0008/075         255       FAIL             8
09D1907     ISDN-TRK    0008/077         255       FAIL             8

Problem Clarification

dropped calls

Cause

Board 09d19 has hardware issues

Solution

Replace Board

Note: Signaling Link State Audit Test (#255)
This test checks the state of critical signaling link hardware components such as DS1 and ATM
CES circuit packs as required by the port.

If Error Code: 8 and Test Result: FAUL : There is a problem with the circuit pack or media module.

 


Avaya -- Proprietary. Use pursuant to the terms of your signed agreement or Avaya policy