ERS 3500: Running a MIB-Walk on an ERS 35xx switch returns a warning for a non-existing Power-Supply


Doc ID    SOLN250364
Version:    2.0
Status:    Published
Published date:    11 Aug 2017
Created Date:    20 May 2014
Author:   
sharma68
 

Details

Running a MIB-Walk on an ERS 35xx (SW v5.1) switch returns a warning for a non-existing Power-Supply
ERS3500(SW: 5.1): Customer reported that while running a MIB Walk for the Power Supply Status (OID: 1.3.6.1.4.1.45.1.6.3.3.1.1.10.4) they are getting a Warning (.11.0: Warning(8)) for the secondary power supply (RPS) even if the RPS unit is not present. Ideally it should be shown as Not Available (notAvail (2)).

Problem Clarification

It is more of a cosmetic issue as the Redundant Power Supply option is not there on 35xx platform.

Cause

The issue is documented in wi01153405

Solution

It is recommended to upgrade to the software release v5.1.3