Error Type 513: ring generator operational status failure. Aux Data values give description:
Aux 2: Shorted
Aux 16: When redundant power supplies are present, the standby ring generator (slot 15) is providing ringing voltage.
Error Type 257: ring voltage not detected on backplane.
Error Type 1: ring generator interchange failed. Run test environment long. Run test board long. Follow the repair procedures.
Error Type 1793: Power supply operational failure. Aux 4: Failure, voltage, temperature, or internal status fault.
Error Type 513: the +5V is out of tolerance (4.75 to 5.25 V (+/- 5%)).
Error Type 769: the -5V is out of tolerance (-4.5 to -5.5 V (+/- 10%).
Error Type 1025: the -48V is out of tolerance (-44.2 to -51.8 V (+/- 8%)).
Error Type 2049: input power failure.
Error Type 2305: aux sig lead failure.
Error Type 513: Ringing Application Test (#48) failure. The terminal equipment is not connected to the circuit pack.