CS1000 : 7.65 : Virtual Trunks Down After Signal Server Replacement


Doc ID    SOLN318637
Version:    1.0
Status:    Published
Published date:    25 Nov 2017
Author:   
tpstone
 

Details

CS1000

X21 7.65

SIgnal Server Replaced

Problem Clarification

 Virtual Trunks Out of Service

VTRK Application not running on Signal Server

Virtual DCH Down

VTRM show no registered trunks in PBX LD 32

Cause

 VTRK Application was turned off during replacement of Signal Server hardware.

Solution

Edit Node settings to enable the VTRK application on Signal Server.  Transmit updates to Node elements and restart applications.


Avaya -- Proprietary. Use pursuant to the terms of your signed agreement or Avaya policy