DEFINITY Made Easy Tools
Issue 3, December 2001
Install and Connect Multi-Carrier Cabinets
Install Auxiliary Cabinet Equipment
The Auxiliary cabinet allows for carrier, 23-in. (58.4 cm) rack, or panel mounting of hardware. The following equipment is furnished with the cabinet:
- Fuse panel -- Distributes -48 VDC power to fused cabinet circuits
- Power receptacle strip -- Provides switched and unswitched 120 VAC receptacles
- DC connector block -- Required when Auxiliary cabinet is powered by an external DC source
- AC to DC power supply -- Converts AC power provided by the AC power strip switched outlet to the required DC voltage
Install equipment inside the cabinet as specified in the CSD. The following optional equipment can be installed:
- Audichron H9040 Wake-Up Announcement System
- 909A/B Universal Coupler
- 7400 Series Data Modules
- Z77A Multiple Data Mounting
- Fan Assembly -- Requires 120 volt AC power
- COMSPHERE 3000-series modems
- External Channel Service Unit (CSU) -- 1 is required for each T1 carrier link
- PagePac Paging System -- 3 models are available. All PagePac models require 120 VAC power.
- Model 15A Announcement System -- see the table for a list of equipment.
The BLD1 circuit pack provides 8 channels with up to 20 seconds of recording time on each channel. The BLD2 circuit pack provides 8 channels with up to 40 seconds of recording time on each channel. Each chassis can be populated with any combination of 2 BLD circuit packs.
The Model 15A Announcement System is FCC registered and does not require a voice coupler.