Return to Task List

  1. To administer the Stratum 3 clock, type change synchronization and press Enter .

  2. Type 3 in the stratum field.

  3. Type the port network number where the TN780 Tone-Clock circuit packs reside in the port network field.


Note: Wait 1 minute for the software to reconfigure the system synchronization.

  1. Verify the results of test 649. If test 649 fails with a code of 2101, then check the wiring for EXTSYN0 and EXTSYN1. Refer to DEFINITY Enterprise Communications Server Maintenance for R10r.

If test 649 is successful, then the system is getting correct timing from the Stratum 3 clock.

Return to Task List