Check for Red LEDs

Return to Task List

  1. Turn on the Stratum 3 clock and wait 40-50 seconds to allow the system to complete the on-board diagnostics before checking LEDs.

  2. If there are any red LEDs, follow the procedures in Stratum 3 Clock LED Indicators.

Stratum 3 Clock LED Indicators

Card
LED Label
Procedure

PAI

REF A

Check that the CI circuit pack on the left is inserted properly. Check wiring for DS1 in carrier "A" which connects the system to the CSU and the External Synchronization Clock at the MDF through a Y-cable assembly. If all else fails to clear the LED then replace the circuit pack.

PAI

REF B

Check that the CI circuit pack on the right is inserted properly. Check wiring for DS1 in carrier B which connects the system to the CSU and the External Synchronization Clock at the MDF through a Y-cable assembly. If all else fails to clear the LED then replace the circuit pack.

PAI

ST A

Replace the ST3 card

PAI

ST B

Replace the ST3 card

CI

FAIL

Check wiring for its associated DS1 reference and replace the circuit pack if necessary

ST3

FAIL

Replace the circuit pack

ST3

LOCK

Ignore this LED

ST3

HOLDOVER

Ignore this LED

ST3

FREE RUN

Ignore this LED

TOCA

FAIL

Replace the circuit pack

TOCA

PORT ALM

Replace the circuit pack if necessary

Return to Task List