DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Set the Data Module Operating Mode

Return to Task List

  1. Connect an RS-232 cable from the Avaya Site Administration computer to the data module.

  2. If you are using an 8400B+, connect the Avaya Site Administration computer to the data module using the supplied adapter cable.

  3. Using a terminal emulator, connect to the serial port to which the data module is connected, and set the emulation to vt100 mode.

  4. Type AT at the prompt and press Enter.

  5. The data module should return an OK. If it does not, be sure that a standard RS-232 or EIA-232 cable is connected (not a null modem cable).

  6. Set the operating mode:

Type of
Data Module
How to set the operating mode

8400B+

Type AT&F and press Enter. Type ATS24=1 and press Enter. Type AT&WØ and press Enter to save the operating mode into non-volatile RAM.

7400A
7400B+

Type AT&F and press Enter. Type AT&WØ and press Enter to save the operating mode into non-volatile RAM.

  1. Disconnect the terminal from the data module and reconnect the data module to the system cabling.

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.