Required hardware for System 75 XE to R8si upgrade
Equipment |
Description |
Quantity |
Notes |
J58890L
|
Enhanced Control Cabinet
|
1
|
L-2 List 25 or newer uses TN794; older carriers use TN794/TN2400 NetCon
|
J58890M
|
Enhanced Duplicated Control Cabinet
|
1
|
Required for critical reliability M-2 List 15 or newer uses TN794; older carriers use TN794/TN2400 NetCon
|
108595638
|
TN790B Processor
|
1 or 2
|
One with standard reliability, two with critical reliability.
|
103557187
|
TN765 Processor Interface
|
1, 2, or 4
|
Provided as required for DCS, CMS, AUDIX, etc.
|
PEC 6300-04X
|
Processor Port Network
|
1
|
EPN upgrade only
|
J58890N
|
Expansion Control Cabinet
|
1
|
EPN upgrade only
|
106647985
|
TN775B Maintenance
|
1
|
EPN upgrade only
|
103557476 848254942
|
TN794 Network Control TN794/TN2400 Network Control
|
1 or 2
|
One with standard reliability, two with critical reliability.
|
103557294 or 103281788
|
TN776 or TN570 Expansion Interface
|
2 or 4
|
EPN upgrade only. 2 for std/high-reliability. 4 for critical reliability. TN570 required with optional packet bus.
|
One type of: 103557096 103557211 103557336 106706955
|
One type of: TN756 Tone-Detector TN768 Tone-Clock TN780 Tone-Clock TN2182 Tone-Clock
|
1 or 2 1 or 2 1 or 2 1
|
One with standard reliability, two with critical reliability.
|
H600-259 G1
|
Intercabinet Cables A, B, and C
|
3
|
Required for critical reliability
|
103557252
|
TN772 Duplication Interface
|
2
|
Required for critical reliability
|
405907015
|
WP-91716 L3 TDM/LAN Cable
|
0 to 3
|
Quantity depends on the number of single-carrier cabinets in the upgraded PPN.
|
105631527
|
AHF110 TDM/LAN Bus Terminator
|
2
|
|
601817448 or 601817422 or 601817430
|
R7/R8 Translations Card:
2 Mbyte Mass-Storage Translation Card (white card) or 4 Mbyte Mass-Storage Translation Card (white card) or 10 Mbyte Mass-Storage Translation Card (white card)
|
1 or 2
|
One with standard reliability, two with critical reliability.
4-Mbyte translation memory cards are required for a system that uses recorded announcements. A 10 Mbyte card is required if a DEFINITY Wireless Business System is installed.
|
63300A
|
FL2P-P-XX Fiber Cable
|
1 or 2
|
EPN upgrade only. 2 cables for critical reliability systems.
|
106455348 or 106455363
|
9823-A or -B Lightwave Transceiver
|
2 or 4
|
EPN upgrade only. 4 tranceivers are required for critical reliability systems.
|
H600-248 G1
|
ICC Cables
|
2
|
EPN upgrade only. Required for critical reliability.
|
846307817
|
Lower Rear Cover
|
1
|
EPN upgrade only. Use in "B" port cabinet in critical reliability system.
|
846307841
|
C Port Label
|
1
|
|
846307958
|
D Port Label
|
1
|
|
106689516
|
TN771D Maintenance/Test
|
1
|
Required in a port slot of a critical-reliability Release 8si PPN with the optional packet bus.
|
846307809
|
Ground Plate
|
1
|
Required for critical reliability
|
846309466
|
DEFINITY Label
|
1
per cabinet
|
|
846408268
|
Earthquake Front Panel
|
1
|
Earthquake protection only
|
846408386
|
Earthquake Ground Plate
|
1
|
Earthquake protection only
|
846408250
|
Stiffener
|
1
|
Earthquake protection only
|
846408243
|
Earthquake Front Mounting Angle
|
1
|