DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Verify the required hardware for a control-carrier replacement [75 small upgrade]

Return to Task List

The equipment in the following table must be on-site before the upgrade begins. Ensure that the translation memory card is current and, if necessary, contains enough memory for recorded announcements.

The TSC cannot source equipment for you.

To place a claim for missing equipment as part of the Streamlined Implementation process, call 1-800-772-5409 and respond to the call prompter, or call the number provided by your Avaya representative.

Required hardware, small System 75 control-carrier upgrade to R8si
Description
Equipment
Quantity

Enhanced Control Carrier

J58890AH

1

TN790B Processor

108595638

1

TN765 Processor Interface

103557187

1 or 2 (Note 1)

TN794 Network Control (depends on control carrier)

103557476

1

TN768 Tone-Clock

TN780 Tone-Clock

TN2182 Tone-Clock

103557211
or
103557336
or
106706955

1

1 (Note 5)

1 (Note 6)

631DB1 Power Supply

106432602

1

982LS Current Limiter

106455504

1

ZAHF4 TDM/LAN Bus Terminator

103960456

2

WP91716 L6 TDM/LAN Cable

J58890A L20

1 (Note 2)

2 Mbyte Mass-Storage Translation Card (White Card)
or
4 Mbyte Mass-Storage Translation Card (White Card)
or
10 Mbyte Mass-Storage Translation Card (White Card)

601817448
or
601817422
or
601817430

1 (Note 3)

TN771D Maintenance/Test

106689516

1 (Note 4)

176A Apparatus Blank (for removed tape drive)

105731202

1

DEFINITY Label

846309466

1

Notes:
  1. Optional. Replaces TN716, TN719, and TN738 if present in the system.

  2. Required only if carrier B is present.

  3. A 4 Mbyte translation card is required for a system that uses recorded announcements. A 10 Mbyte card is required if a DEFINITY Wireless Business System is installed.

  4. Optional. Required for digital trunk testing.

  5. Use TN780 as Tone-Clock for Stratum 3 timing. Also required with the TN780 are the TN748, and TN744 for tone-detection.

  6. The TN2182 Tone-Clock provides tone detection, tone generation, and tone-clock in one circuit pack, and it replaces the TN756, TN768, and TN780 circuit packs, while providing the same functionality as the TN748 and TN420 circuit packs.

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.