DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Set the Clock Options

Return to Task List

There are four sets of option switches on the clock.

  1. Set the options on the Clock Input (CI) circuit pack acording to CI Option Switch Settings.

  2. Set the options on the Stratum 3 Clock (ST3) circuit pack according to ST3 Clock Circuit Pack Option Switch Settings.

  3. Set the options on the Composite Clock Timing Output (TOCA) circuit pack according to Composite Clock Timing Output (TOCA) Circuit Pack.

  4. Set the Stratum 2/Stratum 3 switch to the STRATUM 3 position.

CI Option Switch Settings
Switch
Function
Position

1

T1 Select

OFF = enable (default)
ON = disable

2

CC Select

OFF = enable
ON = disable (default)

3

Framing Select

OFF = ESF
ON = D4 (default)

4

BX.25

OFF = enable
ON = disable (default)

ST3 Clock Circuit Pack Option Switch Settings
Switch
Status/Results

SW1
Minor Alarm Control

OFF = minor alarm never output

ON = minor alarm is output if holdover occurs

SW2
Major Alarm Control

OFF = major alarm is output and fail lamp lights if 5 VDC power is lost and 4 kHz output is lost

ON = major alarm is output and fail lamp lights if 5 VDC power is lost and 4 kHz output is lost and holdover occurs


Note: Only SW 1 and SW2 are used. SW1 controls the output of alarm signals from the Stratum 3 Clock circuit pack.

Composite Clock Timing Output (TOCA) Circuit Pack
Switch
Range
500
1000
1 ft
(0.3 m)
500 ft
(152 m)
1000 ft
(305 m)
1500 ft
(457 m)
2000 ft
(610 m)
2500 ft
(762 m)
3000 ft
(914 m)

OFF

OFF

<-------------------------------------------------->

 

ON

OFF

 

<---------------------------------------------------->

 

OFF

ON

 

<---------------------------------------------------->

 

ON

ON

 

<--------------------------------------------------->


Note: Set switches 1 and 2 according to the distance from the Stratum 3 clock to the DEFINITY System. Set switch 3 to ON. Set switch 4 to OFF.

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.