A console's maximum distance from the system is limited. The maximum distance for a 302C1 console is as shown in Attendant Console Cabling Distances.

Attendant Console Cabling Distances

Enhanced Attendant Console (302C1)
24 AWG Wire
(0.5106 mm2)
26 AWG Wire
(0.4049 mm2)
Feet
Meters
Feet
Meters

With Selector Console

Phantom powered

800

244

500

152

Locally powered

5000

1524

3400

1037

Without Selector Console

Phantom powered

1400

427

900

274

Locally powered

5000

1524

3400

1037

Auxiliary Power


Caution! Do not use the 329A power unit for the attendant console.

The nonessential functions of an attendant console and its optional 26A1 or 24A1 selector console derive their power from an auxiliary power source. Of the maximum of 27 attendant consoles, 3 of the consoles can derive auxiliary power from the system and through the auxiliary cable located in the trunk/auxiliary field. Provide auxiliary power for a primary attendant console through this cable so the console remains fully operational during short power outages.


Note: For a console to realize the longest possible nominal battery holdover of 10 minutes, the console's TN754B or TN413 Digital Line circuit pack should reside in an EPN's duplicated control cabinet.

An attendant console can also derive auxiliary power from:

A console's maximum distance from its auxiliary power source is:

Hard-Wire Bridging

Analog type hard-wire bridging is not allowed for four-wire (only) DCP endpoints. Hard-wire bridging provides no way of combining the digital output of two bridged DCP sets. Also, a bridged endpoint causes degradation of the DCP signal.


Caution! Bridging or paralleling these endpoints can cause electrical damage to the consoles or cause the circuit pack to remove power from the consoles.

Dual Wiring of Two-Wire and Four-Wire Endpoints

Do not simultaneously wire a two-wire and four-wire endpoint to the same equipment location in an MDF. The DEFINITY System uses separate circuit packs to interface two- and four-wire endpoints.