Auxiliary equipment that connects to the MDF can be mounted inside the Auxiliary cabinet. The equipment connects to an ED-1E1443-10 (Group 1) intraconnection panel mounted in the cabinet. This intraconnection panel consists of a 110-type 100-pair wiring block. Auxiliary equipment is connected to the 110-type wiring block. The wiring block is pre-wired to four 25-pair female connectors mounted on the outside rear of the cabinet.

  1. Install "D" rings on the wall between the cable slack manager and the terminal/connecting blocks mounted on the MDF.

  2. Install a self-sticking port label on the rear of each connector on the B25A connector cable. See Self-Stick Label on 25-Pair Cable Connector.

  3. Labels should be positioned so they will not be obscured by the cabinet connector retainers.

  4. At the rear of the Auxiliary cabinet, connect 1 end of the connector cable to the assigned connector.

  5. Route the cable down the rear of the cabinet and through the cable slack manager to the MDF.

  6. At the MDF, connect the other end of the cable to the assigned terminal/connecting block connector.

  7. Store the excess cable in the cable slack manager.

  8. Repeat Steps 2 through 6 until all cables are installed.

Self-Stick Label on 25-Pair Cable Connector

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.