Install and Wire Telephones
Auxiliary Connector Outputs
Connect a 25-pair cable from the AUX connector on the back of the control carrier to a connecting block on the trunk/auxiliary field.
Auxiliary Lead Appearances at AUX Connector shows the Control Carrier outputs cable pinouts. The Control Carrier AUX connector outputs include:
- Alarm monitoring for the auxiliary cabinet
- Seven -48 VDC power sources for emergency transfer units
- Three -48 VDC power sources for remotely powering three attendant consoles or telephone adjuncts
- The remote management terminal interface trunk connection location
- A relay contact that actuates a customer-supplied light, bell, or similar device. The relay can activate when a major, minor, or warning condition occurs. The device connected to the alarm leads must not exceed a rating of 30 VAC rms or 60 VDC at 0l75 amps.
Auxiliary Lead Appearances at AUX Connector shows the pinouts for an external alarm.
Port Circuit Pack and Telephone Pin Designations provides port circuit pack and telephone pin designations.