- Mount the 127A vertically near the main distribution frame (MDF). The 127A case has tabs for screw-mounting and cutouts for snap-mounting the unit in a 89-type mounting bracket.
- Attach a ground wire (required) between the 127A and the MDF ground terminal bar. The wire must be green/yellow and no smaller than 0.75 mm
2 (18 AWG).
- Strip both ends of an appropriate length of wire.
- Insert one end of the wire into the MDF ground bar and secure.
- Insert the other end into the screw-connection in the end of the 127A and secure. See 127A BALUN Coaxial Adapter.
- Connect the H600-348 quad cable to the 4 DB-15 connectors provided on the 127A adapter.
- Connect the transmit connectors to the connectors marked T and the receiver connectors to the connectors marked R.
- Connect the other end of the cables to whatever connects to the network.
127A BALUN Coaxial Adapter
Figure Notes:
- 127A BALUN coaxial adapter
- Connect to quad cable (H600-348 or similar)
- BCN Connections to E1 network equipment
- Single-point ground connection
-
>= 0.75 mm
2 (18 AWG) ground wire to ground terminal at MDF
Return to Task List