DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Verify system status [G3V4 to R10si]

Return to Task List

  1. Verify that system status is normal.

  2. Execute status system 1 (If status is not normal, take the needed corrective actions.)

  3. Verify that the system is alarm-free.

  4. Execute display alarms (If the system is not alarm-free, take the needed corrective actions.)

  5. Identify and record customer-placed busy-outs.

  6. Execute display errors (Examine the error log and record the error 18s that identify the busy-outs placed by the customer.)


Note: You will restore the customer-placed busy-outs after you have upgraded the system.

  1. For a system that has existing BX.25 links that are being retained after the upgrade: identify and record them.

  2. Execute display communication-interface links

  3. Execute the following commands and verify that the information is correct:

  4. list station

    list trunk-group

    list hunt-group

    list data-module

    For upgrades from systems later than G1, list ars analysis

    For a system with Expert Agent later than G3V3, list agent

    If any command does not complete successfully, escalate the problem immediately.

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.