G3iV4 to R10si (On-Site)
Introduction
This section provides the information necessary to upgrade a DEFINITY
® G3iV4 system with a single-carrier or a multicarrier PPN to a DEFINITY R10si system using the on-site upgrade method.
References
For hardware details, see
DEFINITY Enterprise Communications Server System Description and When to use the TN2401 versus the TN2401/TN2400 sandwich pack.
About circuit-pack carriers
If the system currently being upgraded was originally a System 75, the circuit-pack carrier or cabinet is no longer supported. This table identifies the obsolete carriers and cabinet.
Before you begin the upgrade
Review the Preparation and process steps carefully. These tables describe the tasks that must be completed before the upgrade visit and who is responsible for them.
To prevent the most common upgrade problems, be sure that you have
- identified the correct TDM bus cables and terminators for the upgraded system
- verified si expansion interface compatibility for packet bus applications:
If the new si system will have one or more expansion port network cabinets and will run any packet applications,
do not reuse the TN776 expansion interface circuit packs; they must be replaced with TN570 circuit packs.
- checked for software upgrade compatibility and identified any patches that need to be re-applied
- create the license file with RFA
Task List: G3iV4 to R10si
Use this task list when you are upgrading a DEFINITY G3iV4 PPN to an R10si PPN.
Ensure that these tasks are complete
before the upgrade visit:
- Verify the required hardware [G3V4 to R10si]
- Provide the required tools [G3V4 to R10si]
- Go to the RFA website
Perform these tasks
during the upgrade visit:
- Duplicate switch's system software
- Check existing software load [G3V4 to R10si] to identify any software patches.
- Verify system status [G3V4 to R10si] Record any customer-placed busy-outs.
- Disable scheduled maintenance and alarm origination [G3V4 to R10si]
- Record all links and remove only ISDN interface links [G3V4 to R10si]
- Disable TTI [G3V4 to R10si] if it is enabled.
Do not skip this step!
Translations can be corrupted if TTI is enabled. Confirm that TTI is completely disabled before you continue!
- Save translation [G3V4 to R10si] or Save translation, duplicated system [G3V4 to R10si]
- If necessary, Save announcements (TN750 or TN750B only) [G3V4 to R10si]
- For systems so equipped: Shut down DEFINITY LAN Gateway [G3V4 to R10si]
- For systems so equipped: Shut down DEFINITY AUDIX system [G3V4 to R10si]
- Power down PPN [G3V4 to R10si] and unseat any adjuncts