DEFINITY Made Easy Tools
Issue 3, December 2001
Install and Administer Trunks
Install CAMA/E911 Trunk
The CAMA/E911 feature requires the TN429C/D CO trunk circuit packs (or later suffix).
Port Networks (PNs) that include TN429C circuit packs used to interface to CAMA trunks require some CPTR resources to be either TN744D V2 or TN2182B circuit packs, since TTR/CPTR or General Purpose Tone Receiver (GPTR) resources are selected from the pool available in the PN when needed.
Compatibility Tone Clock, TTR/CPTR, and GPTR Circuit Packs denotes which of these circuit packs are compatible and which are not affected.