DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Power up and set date, time, and daylight savings rule [75 XE upgrade]

Return to Task List


Caution! It may be necessary to reseat circuit packs. To prevent damage from static electricity, always wear an Electromagnetic Compatibility (EMC) wrist strap (comcode 900698226) when handling all system components.


Note: To prevent unnecessary trouble tickets, do not enable the system alarms (Alarm Origination feature) until all installation and administration procedures are completed.

  1. Verify that the write switch on the Translation Flash-Memory Card (translation card) is positioned down so the card can be written to. Install the R8si translation card into the TN794 circuit pack in the direction indicated by the arrow on the label.


Note: If the system is high or critical reliability, power up the EPN cabinet first, then the PPN cabinet. Always power up the control cabinet last.

  1. Power up the AC- or DC-powered system.

System
Steps

AC


  1. Set the circuit breakers on the AC power panel to ON.

  2. Set the cabinet circuit breakers to ON.

  3. This starts the system initialization and test. All red LEDs on the circuit packs go on and then off.

DC



  1. At the DC Battery Cabinet (if installed), set the circuit breaker to ON.

  2. At the DC Power Cabinet, set the circuit breaker(s) on the rectifiers to ON.

  3. This starts the system initialization and test. Some red LEDs may be turned on, but they are turned off during the boot-up process. No action is required.

The results of system tests display on the monitor.

  1. Verify that all tests pass.

  2. If any of the terminal messages indicate a test has failed or if the message spe down mode is displayed, refer to the DEFINITY Enterprise Communications Server Maintenance manual to clear the trouble.

  3. Type set time and press Enter.

  4. See Typical Date and Time Screen.

  5. Enter the date information and the time in 24-hour format. Enter either daylight saving time or standard time, depending on the current time in your time zone. If your area does not use daylight saving time, set the value of Rule to 0; otherwise, set Rule to 1. Press Enter to set the date and time and ensure that the system boots properly.

Typical Date and Time Screen

                   DATE AND TIME
 DATE
      Day of the Week: Tuesday    Month: June 
     Day of the Month: 26          Year: 2000 
 
 TIME
     Hour: 20 Minute: 30  Second: XX   Type: standard
           Daylight Savings Rule: 1
 

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.