DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for R9 Go to Installation for MCC Go to Installation for SCC



Power up and set date, time, and daylight savings rule [R9si]

Return to Task List


Caution! It may be necessary to reseat circuit packs. To prevent damage from static electricity, always wear an Electromagnetic Compatibility (EMC) wrist strap (comcode 900698226) when handling all system components.


Note: To prevent unnecessary trouble tickets, do not enable the system alarms (Alarm Origination feature) until all installation and administration procedures are completed.

  1. On an SCC, power up the AC- or DC-powered system.

    On an MCC, plug in the right, then left power plugs on either side of the control carrier.

For Single Carrier Cabinets
System
Steps

AC


    1. Set the switch on the AC power panel to ON position (up).

    2. Set the cabinet circuit breakers to ON.

    3. This starts the system initialization and test. All red LEDs on the circuit packs go on and then off.

DC



    1. At the DC Battery Cabinet (if installed), set the circuit breaker to ON.

    2. At the DC Power Cabinet, set the circuit breaker(s) on the rectifiers to ON.

    3. This starts the system initialization and test. Some red LEDs may be turned on, but they are turned off during the boot-up process. No action is required.

The results of system tests display on the monitor.

  1. Verify that all tests pass.

  2. If any of the terminal messages indicate a test has failed or if the message spe down mode is displayed, refer to DEFINITY Enterprise Communications Server Release 9 Maintenance for R9si to clear the trouble.

  3. Log in as craft.

  4. Type set time and press Enter.

  5. See Typical Date and Time Screen.

  6. In the Type: field, type standard or daylight savings.


Note: The default daylight savings rule is 0, no daylight savings.

  1. In the Daylight Savings Rule: field, set the rule value. If your area uses daylight savings time, set the value to 1; otherwise, use the default setting of 0.

  2. Press Enter to set the time.

Typical Date and Time Screen

                   DATE AND TIME
 DATE
      Day of the Week: Tuesday    Month: June 
     Day of the Month: 26          Year: 2000 
 
 TIME
     Hour: 20 Minute: 30  Second: XX   Type: standard
           Daylight Savings Rule: 1
 

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for R9 Go to Installation for MCC Go to Installation for SCC
Copyright 2000 Avaya Inc
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.