DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for R9 Go to Installation for MCC Go to Installation for SCC



New for R9csi

This section includes:

Minimum required hardware for R9csi

You need the following minimum required hardware to upgrade to Release 9csi software.

Equipment
Code
Comcode
Notes

Basic processor cabinet

J5889OT-1
--

Contains the following circuit packs:

  • TN2402 (processor)

  • TN2182B (tone clock)

AC Power unit

650A
107949364


New control hardware for R9csi

The following upgrade equipment is new to Release 9csi.

Equipment
Code
Comcode
Notes

R9csi Generic Program Card (orange)

J58890TG-1, L300
108724931

The card is thicker than the old program card

8-Mbyte translation flashcard (white)
16-Mbyte translation flashcard (white)1
48-Mbyte translation flashcard (white)

J58890TG-1, L100
108724907
J58890TG-1, L200
108724915
J58890TG-1, L300
108724923

The cards are thicker than the old translation cards; the have more memory. The old translation cards are read only in the new processor.

Processor

TN2402
108516683

The processor has a wider face plate to accept the thicker flashcards.

1
Required for systems using recorded announcements or with a DEFINITY ECS Wireless Business System installed.

New procedures for R9csi

Some upgrade procedures were reordered and the steps within the procedure better defined. Check the task list at the beginning of the upgrade section for the current order.

Procedure

Steps

Notes

Check IP Softphones (R8 to R9 only) [R9csi]

Type display system-parameters customer-options and press Enter. Go to the Maximum IP Registrations by Product ID screen (last screen) and write down the number listed in the IP_Soft field. The number must be verified at the end of the upgrade.

For upgrading R8 to R9 only.

For customers having IP softphones only.

The maximum number of registered IP softphones may default to 1 after an upgrade. Note the number BEFORE the upgrade.

Administer ID Softphones within Enable Customer Options and Alarm Origination to INADS [R9csi]

For R8 to R9 only and customers having IP softphones, go to the System Parameters Customer-Options, Maximum IP Registrations by Product ID screen (last screen) and verify that the number listed in the IP_Soft field did not default to 1. If it did, get the number from field technician and type it in.

For upgrading R8 to R9 only.

For customers having IP softphones only.

Requires init login.

The maximum number of registered IP softphones must match the pre-upgrade number.

Upgrade tips for R9csi

The following upgrade tips were generated from problems identified in the laboratory or during early introduction.


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for R9 Go to Installation for MCC Go to Installation for SCC
Copyright 2000 Avaya Inc
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.