DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Expansion Port Network (All Reliability Options)

Return to Task List

  1. Remove the TDM Bus Terminator from Slot 18 of Control Cabinet A (PPN) and move it to Slot 17 on the top port cabinet. See Connections for High or Critical Reliability Systems.

  2. Connect the supplied TDM Bus Cables (WP-91716 L3) as shown.

Connections for High or Critical Reliability Systems

Figure Notes:
      1. AHF110 TDM Bus Terminator (Slot 17)

      2. TDM/Local Area Network (TDM/LAN) Pinfield (Slot 00)

      3. TDM bus Cable (WP-91716 L3)

      4. Port Cabinet

      5. Control Cabinet A Position

      6. AHF110 TDM Bus Terminator (Slot 03)

      7. Slot 18

      8. Inter-Cabinet Cables (ICC) B and C (H600-259-G1)

      9. Duplicated Control Cabinet B Position

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.