Programming a CTI Link
System Programming includes complete information about programming a CTI link. When you program a CTI link, ensure that no telephone, fax, videoconferencing system, or digital communications equipment is connected to the MLX port. A working or potential system programming or operator position extension cannot be programmed as a CTI link; therefore, a CTI link cannot be programmed on the first or fifth extension jack of an MLX module. A CTI link can be programmed on port 2, 3, 4, 6, 7, or 8 of the MLX module.
In order to program a new CTI link, or remove an existing one, you must first busy-out the slot where the MLX module for the CTI link is located or where you plan to install it. For this reason, if you program the CTI link using an MLX-20L telephone programming console, that console must not be connected to the same MLX module where you have installed, or plan to install, the CTI link. (See Programming for more information about programming options. For details about busying-out a slot in the control unit, see the System Manager's Quick Reference.)
![]() |
If your system includes only one MLX extension module, you must use a PC and System Programming and Maintenance (SPM) software to program the CTI link. |
![]() |
CAUTION! |
|
The Maintenance procedures that you use to busy-out and restore a module are normally reserved for Avaya technicians only. |
When you add a CTI link, the system performs the following actions: